  Technical parameters 

1. The working voltage is three-phase AC380V for water pump, and 220V for the rest single-phase AC, with reliable grounding. Power: 7KW

2. Working water pressure 0. 01Mpa’ 2. OMpa adjustable,

3. Water pressure accuracy 1%

4. Electricity power up to 5KW

5. Test medium water

6. Control system PLC + computer

7. Test station: 2 stations

8. Test product range Water inlet valve, drain valve

9. Machine station: 2 stations. The two stations are parallel, and each station does not interfere with each other during the test to ensure the accuracy of the test process and test results

10. There is a filter screen under the equipment to prevent the test subject from running away and blocking the drain outlet.

11. The equipment has a rapid drainage function to prevent water overflow.

 12. The glass pipe connected to the water inlet valve is transparent and easy to observe and cannot be easily damaged:

13. The equipment has the function of rapid drainage to prevent water overflow.

14. The equipment is equipped with a standard water tank placement table, which needs to be kept flat, and the table surface is about 850 mm from the ground. Openings under the countertop allow water to drain from the toilet.

15. Appearance color: the appearance of stainless steel surface brushing

16. Equipment size (approx.): 2000*1200*1800mm

17. Water tank: 60L

Control system

The machine is composed of PLC, computer, water pump, cylinder, solenoid valve and other control components and professional test procedures, and the test record data can be imported into the laboratory management system.

Product Description:

Thread torque and tensile strength, inlet valve, flushing tank (including hidden water tank) inlet flow detection, tightness testing, pressure resistance testing, drainage flow detection (including hidden water tank – use weighing method for drainage flow detection), tightness testing, safe water level detection, external water tank front thrust.

Comply with the standards and terms

GB/T26730-2011 5.2.1.3 Appendix B Thread torque and tensile strength

GB/T26730-2011 5.2.3. 6. 8 Inlet flow

GB/T26730-2011 5.2.4. 6.9 Tightness

GB/T26730-2011 5.2.5、 6. 1 Pressure resistance

GB/ T26730-2011 5.2.8、6. 13 Turn the function back on

GB/T26730- 2011 5.3.1, Appendix B Drain valve joint strength

GB/T26730-2011 5.3. 4、6. 20 Drainage flow

GB/T26730 -2011 5.4.1. 5.4.10.2 Safe water level

GB/T26730- -2011 5. 4.6、6. 23 loads

GB/T26730- -2011 5.4.7、6. 24 Operating force

of drive mechanism GB/T26730- -2011 5. 4.8 Appendix F External Water Tank Front Thrust
GB/T26730-2011 5.4.10.4. 6. 26 Deformation
resistance of concealed water tank
GB/T26730 2011 5. 4.10.5.6. 27 Impact resistance