LT-WY66 Ceramic Basin Overflow Test Test
Control system
This machine adopts touch screen and corresponding test monitoring and recording programs, and is composed of PLC, water pump, etc. control system, and the test program can be run automatically.
Technical Parameters:
1. Pressure sensor: range 0~1.0MPa, accuracy 0.5 level, resolution 0.01MPa acquisition frequency 900Hz, to ensure the accuracy of water pressure;
2. Flow measurement range: 0~50L/min, accuracy 0.8;
3. The equipment is equipped with a failure judgment device to automatically record the failure time;
4. The effluent height can be adjusted with the change of sample height;
5. The equipment is adjusted according to the size of the basin, which can make the basin place normally, and the adjustment range is 20cm-130cm;
6. Equipment height length * width * height: about 1500*1000*1800mm; Equipment height: 1800mm understanding: (the equipment cup is screwed up, the equipment wheels are suspended, and the space under the equipment should have a space of 150mm; the overall height of the equipment is 1800mm)
7. The equipment has universal wheels, the level is adjustable, and the equipment ground clearance is 150mm
8. Add protective cover (aluminum profile + acrylic sheet)
Meets standards
Sanitary ceramics GB6952-2015 Sanitary ceramics 8.9 Overflow test of washbasin, bidet and sink