LT-WY26 bathtub hot water resistance, hot and cold shock testing machine
Technical parameters
Serial number item name requirements
1. Working voltage: 380±10%V/50Hz
2. Electricity power 11KW
3. The test range and accuracy of the temperature sensor are 0~100°C, and the accuracy is Class A
4. WATER TANK VOLUME (L): ≥80CM2
5. The slope of the test bench is 2mm/m
6. The heater power is 9KW
Product Description:
This machine is mainly used to measure the tightness, drainage performance, full deformation of water and hot water resistance test of bathtub. The lower end of the bench contains high-strength casters, and the bench can be disassembled and moved separately for on-site installation.
Control system
This machine adopts PLC, touch screen (optional computer), high-temperature water pump, inverter, high-precision heating system and other control components and professional test procedures to form a control system.
Comply with the standards and terms
Category, Standard Name, Standard Terms
Bathtub JC/T 779-2010 6.8 Impact resistance
Bathtub JC/T 779-2010 6.9 Hot water resistance
Bathtub JC/T 779-2010 6.10 deformed when full of water
Bathtub JC/T 779-2010 6.11 Drainage performance