LT-WY20 Water tank accessories life testing machine
Technical parameters |
|||
The serial number |
According to project name |
Parameters |
|
1 |
operating voltage |
Water pump three AC380V, the rest single-phase AC220V, with reliable grounding. |
|
2 |
Working Air Pressure |
External connection,0.3MPa ~ 0.6MPa |
|
3 |
Power consumption |
Max 5KW |
|
4 |
dielectrometer |
Cold water: external; Hot water: room temperature water ~ 90℃ (controllable) |
|
5 |
upper computer |
Computer (touch screen optional) |
|
6 |
Test station |
4 work stations |
|
7 |
Test product range |
Water inlet valve and drainage valve |
|
8 |
Infrared stealth material |
Aluminum profile + aluminum-plastic sealing plate |
|
9 |
actuating device |
air cylinder |
|
10 |
water pump |
Static pressure 0.02 ~ 1.6MPa can be provided |
|
11 |
Dimensions |
Length: 2750mm; Width: 1180mm; Height: 1800mm |
|
Compliance with standards and terms |
|||
category |
The name of the standard |
Standard terms |
|
Gravity flush device and sanitary ware rack |
GB26730-2011 |
6.16 Durability test |