LT-WY202-A3 Sanitary ceramic comprehensive performance testing machine
Technical Parameters
The serial number | According to project name | Want to ask |
1 | Work pressure | Pressure 0.05 ~ 0.9mpa |
2 | Hydraulic resolution | 0.001 MPa |
3 | Flowmeter range 1 | 3 ~ 40 l/M |
4 | Flowmeter range 2 | 20 ~ 240 l/M |
5 | Flowmeter accuracy | 1% |
6 | Weighing scale | 0 ~ 30kg (0 ~ 20L) |
7 | The weighing accuracy | 20 g (0.02 L) |
8 | Time range | 1 second ~ 60 minutes can be set at will |
9 | Time precision | 0.1 seconds |
10 | The test medium | The normal temperature water |
11 | Hydraulic stability | ± 0.05mpa (less than 0.5mpa), ± 0.1mpa (more than 0.5mpa) |
12 | Hydraulic digital display instrument | Display accuracy 0.001mpa |
Water temperature digital display instrument | Display accuracy 0.1℃ | |
14 | Current digital display instrument | Display accuracy 0.1a |
15 | Voltage digital display instrument | Display accuracy 1V |
Compliance with standards and terms |
category | The name of the standard | Standard terms |
Sanitary ceramics | Sanitary ceramics | 8.8.3 determination of water consumption in urinals |
Sanitary ceramics | Sanitary ceramics | 8.8.4 ink line test |
Sanitary ceramics | Sanitary ceramics | 8.8.5 discharge test of toilet ball |
Sanitary ceramics | Sanitary ceramics | 8.8.6 toilet granule test |
Sanitary ceramics | Sanitary ceramics | 8.8.7 mixed media test for toilet |
Sanitary ceramics | Sanitary ceramics | 8.8.8 transport characteristic test of drainage pipe |
Sanitary ceramics | Sanitary ceramics | 8.8.9 water seal recovery test |
Sanitary ceramics | Sanitary ceramics | 8.8.10 sewage replacement test |
Sanitary ceramics | Sanitary ceramics | 8.8.11 test of half flush toilet paper for double flush toilet |
Sanitary ceramics | Sanitary ceramics | 8.8.12 squat toilet discharge function test |
Sanitary ceramics | Sanitary ceramics | 8.8.13 anti-splash test for squatting toilet |
Sanitary ceramics | Sanitary ceramics | 8.9 overflow test for face washer, body cleaner and washing tank |
Sanitary ceramics | Sanitary ceramics | 8.11 test for sealing of toilet connection |
Non-contact toilet flush valve | Non-contact water supply appliance | 8.10.2 water flow of urinal flush valve |
Non-contact toilet flush valve | Non-contact water supply appliance | 8.10.3 water flow of lavatory flushing valve |
Gravity type flushing device and sanitaryware rack | Gravity flush device for sanitaryware and sanitaryware rack | 6.22 determination of rated flush capacity of flushing tank |
Pressure flushing device | GB/T 26750-2011 | 7.1.1.4 hydration ratio |
Pressure flushing device | GB/T 26750-2011 | 7.1.1.5 operation mode |
Pressure flushing device | GB/T 26750-2011 | 7.1.3.1 inlet water flow test |
Pressure flushing device | GB/T 26750-2011 | 7.1.3.2 water inlet stability test |
Pressure flushing device | GB/T 26750-2011 | 7.1.3.3 sealing performance test |
Pressure flushing device | GB/T 26750-2011 | 7.1.3.9 overflow performance test |
Pressure flushing device | GB/T 26750-2011 | 7.2.4.1 sealing performance test |
Pressure flushing device | GB/T 26750-2011 | 7.2.4.2 strength and performance test |
Pressure flushing device | GB/T 26750-2011 | 7.2.4.3 determination of flushing water consumption |
Pressure flushing device | GB/T 26750-2011 | 7.2.4.4 flush maximum instantaneous flow test |
Pressure flushing device | GB/T 26750-2011 | 7.2.4.7 operational performance test |
Pressure flushing device | GB/T 26750-2011 | 7.3.8 sealing performance test |
Pressure flushing device | GB/T 26750-2011 | 7.3.9 strength performance test |
Ceramic plumbing fixtures | ASME/CSA B45.1 A112.19.2-2013-13 | 6.6 Overflow test |
Ceramic plumbing fixtures | ASME/CSA B45.1 A112.19.2-2013-13 | 6.9 to be seal test |
Ceramic plumbing fixtures | ASME/CSA B45.1 A112.19.2-2013-13 | 7.2 Trap seal depth determination test |
Ceramic plumbing fixtures | ASME/CSA B45.1 A112.19.2-2013-13 | 7.3 Trap seal restoration test |
Ceramic plumbing fixtures | ASME/CSA B45.1 A112.19.2-2013-13 | 7.4 Water consumption test |
Ceramic plumbing fixtures | ASME/CSA B45.1 A112.19.2-2013-13 | 7.5 Granule and ball test |
Ceramic plumbing fixtures | ASME/CSA B45.1 A112.19.2-2013-13 | 7.6 Surface for wash test |
Ceramic plumbing fixtures | ASME/CSA B45.1 A112.19.2-2013-13 | 7.7 Mixed media test |
Ceramic plumbing fixtures | ASME/CSA B45.1 A112.19.2-2013-13 | 7.8 Drain line transport characterization test |
Ceramic plumbing fixtures | ASME/CSA B45.1 A112.19.2-2013-13 | 7.9overflow test for gravity flush tanks |
Ceramic plumbing fixtures | ASME/CSA B45.1 A112.19.2-2013-13 | 7.10 term extraction test |
Ceramic plumbing fixtures | ASME/CSA B45.1 A112.19.2-2013-13 | Consistent water level test |
Ceramic plumbing fixtures | ASME/CSA B45.1 A112.19.2-2013-13 | 7.12 Fill valve shutoff integrity test with increased water pressure |
Ceramic plumbing fixtures | ASME/CSA B45.1 A112.19.2-2013-13 | Adjustablility test for tank-type gravity water closets with original equipment |
Ceramic plumbing fixtures | ASME/CSA B45.1 A112.19.2-2013-13 | Adjustablility test for tank-type gravity water closets with aftermarket closure seals |
Ceramic plumbing fixtures | ASME/CSA B45.1 A112.19.2-2013-13 | 8.3 Trap seal depth determination test |
Ceramic plumbing fixtures | ASME/CSA B45.1 A112.19.2-2013-13 | 8.4 Surface for wash test |
Ceramic plumbing fixtures | ASME/CSA B45.1 A112.19.2-2013-13 | 8.5 Dye test |
Ceramic plumbing fixtures | ASME/CSA B45.1 A112.19.2-2013-13 | 8.6 Water consumption test |