LT-WY05 Water nozzle life testing machine
Technical parameters |
||
The serial number |
According to project name |
Parameters |
1 |
Operating voltage |
Water pump, heating, cooling three-phase AC380V, the rest single-phase AC220V |
2 |
Working Air Pressure |
External connection,0.3MPa ~ 0.6MPa |
3 |
Power consumption |
Max 15KW |
4 |
dielectrometer |
Cold water: external; Hot water: room temperature water ~ 90℃ |
5 |
upper computer |
Computer |
6 |
Test stations |
optional |
7 |
Test product range |
1. Single handle double control water nozzle; 2. Single handle single control nozzle 3. Double handle double control nozzle; 4. Intelligent water nozzle |
8 |
External material |
Aluminum profile frame & aluminum-plastic sealing plate |
9 |
Actuating device |
Servo motor + cylinder |
10 |
Angular range and accuracy |
Range 0 ~ 270°, accuracy: 0.2° |
11 |
Flowmeter |
0~30L/min |
12 |
torque sensor |
0~10N.M |
13 |
water pump |
It can provide 0.02 ~ 1.0Mpa |
14 |
Dimensions |
According to the number of stations |
Compliance with standards and terms |
||
Category |
The name of the standard |
Standard terms |
Ceramic plate seals water nozzle |
GB 18145-2014 |
8.6.9.1 Life test of water tap switch |
GB 18145-2014 |
8.6.9.2 Switch Life Test |
|
Delay self-closing nozzle /Induction nozzle |
QB/T 1334-2013 |
8.10.1 Delay the life of the self-closing water nozzle |
Non-contact water nozzle |
CJ/T 194-2014 |
8.17.1 Life of water nozzle and shower |
Plumbing supply fitting |
ASME A112.18.1-2018/CSA B125.1-18 |
5.6.1.2 Valves or controls |