LT-WY01 Water nozzle flow sensitivity testing machine
Technical parameters |
||
The serial number |
According to project name |
Parameters |
1 |
Operating voltage |
Water pump, heating, cooling three-phase AC380V, the rest single-phase AC220V |
2 |
Working Air Pressure |
External connection,0.3MPa ~ 0.6MPa |
3 |
Power consumption |
Max 18KW |
4 |
dielectrometer |
Water: 5 ~ 20℃, 38℃, 60℃ (3 tanks) |
5 |
upper computer |
Computer |
6 |
Test stations |
Simplex position: water nozzle flow, sensitivity (test Angle can be adjusted to meet the sensitivity test of the handle open, side open and 45 degree open three structures of water nozzle.) |
7 |
Test product range |
Water nozzle, shower nozzle |
8 |
External material |
Aluminum profile frame + Aluminum plastic sealing plate (stainless steel) |
9 |
Actuating device |
Servo motor + cylinder |
10 |
Flowmeter |
Measuring range 0-30L/min, measuring accuracy 0.1L/min |
11 |
Water pump |
It can provide static pressure of 0.05 ~ 1.0MPa |
12 |
Dimensions |
Length: 2350mm; Width: 1100mm; Height: 1800mm |
Compliance with standards and terms |
||
Category |
The name of the standard |
Standard terms |
Ceramic plate seals water nozzle |
GB 18145-2014 |
8.6.3.1 flow rate |
GB 18145-2014 |
8.6.3.2 Sensitivity (for single-handle dual control water nozzle) | |
GB 18145-2014 |
8.8.1.1 Flow Rate of the delayed self-closing faucet | |
Non-contact water nozzle |
CJ/T 194-2014 |
8.10.1 Flow rate of water nozzle and shower |
Non-contact induction water supply apparatus |
JC/T2115-2012 |
7.7.1 Flow performance test of water nozzle and shower |
water nozzle |
GB25501-2010 |
5 Test methods |
shower |
GB 28378-2012 |
5.1 Traffic uniformity Test |
shower |
GB 28378-2012 |
5.2 Traffic Test |
thermostatic faucet |
QB 2806-2017 |
10.7.3 Flow Test |
Delay self-closing nozzle |
QB/T 1334-2013 |
8.8.1.2 Sensing the flow of the water nozzle |
QB/T 1334-2013 |
8.8.1.3 Flow of other water taps | |
QB/T 1334-2013 |
8.8.2 Sensitivity (for single handle and double control water nozzle) |