High & Low Temperature Explosion Proof Test Case
Executive standard
1. GB10589-2008 Low temperature test chamber technical conditions
2. GB11158-2008 technical conditions for high temperature test chamber
3. GB10592-2008 High and Low Temperature Test Chamber Technical Conditions
4. GJB 150.3A-2009 Environmental test methods for military equipment laboratories Part 3: High temperature test
5. GJB 150.4A-2009 Environmental test methods for military equipment laboratories Part 4: Low temperature test
6. GB 2423.1-2008 Environmental testing Part 2: Test method A low temperature
7.GB He 2423.2-2008 Environmental Testing Part 2: Test Method B High Temperature
8. GB 31241-2014 Safety requirements for lithium-ion batteries and battery packs for portable electronic products
9. GB 31485-2015 Safety Requirements and Test Methods for Traction Batteries for Electric Vehicles
Characteristic
1. Adopt advanced measurement device, the controller adopts large-scale color liquid crystal man-machine touch conversational LCD interface controller, which is easy to operate, easy to learn, stable and reliable, and the completed system operation status and setting program curve are displayed in Chinese and English.
2. There are two test holes with a diameter of 100mm in the middle of each layer of the left and right sides of the cabinet, which can be used for external power load wiring test components.
3. Fully automatic high-precision loop temperature control system, any movement of the machine, complete PLC lock processing, all adopt PID automatic calculation control, high temperature control accuracy.
4. The advanced and scientific air circulation design makes the temperature in the experiment box uniform and avoids any dead angle; the complete safety protection device avoids any possible safety hazards and perfectly realizes the full linear control of the temperature.
5. When an abnormal state occurs in the status display and curve display during operation, the fault point and cause will be automatically displayed on the screen immediately and the troubleshooting method will be provided.
6. The refrigeration system adopts a cascade high-efficiency low-temperature circuit heat exchange design, and the refrigeration unit adopts a low-noise design of imported compressors from Europe and America, and uses green environmental protection (HFC) refrigerant R404A with zero ozone coefficient.
7. The water cooling equipment will not affect the performance of the equipment due to the temperature change of the environment, which greatly improves the stability of the equipment.
Specifications and models |
|||||||||
Introduction to Controller Functions |
Original imported LCD touch screen display, PID temperature control instrument with high-precision dry-wet bulb converter, independent temperature and humidity control, compatible with electronic temperature and humidity sensors, input mode: 4-20mA or 0-5V | ||||||||
Model selection |
LT-TH series |
||||||||
Specifications |
80 |
120 |
150 |
225 |
306 |
408 |
800 |
1000 |
|
Temperature Range |
A:+25℃~+150℃;R:-20℃~+150℃;F:-40℃~+150℃;S:-60℃~=150℃ (Lowest: -80℃) |
||||||||
Temperature stability |
±0.5℃ |
||||||||
Temperature uniformity |
±1.5℃ |
||||||||
Temperature deviation |
≤±2℃ |
||||||||
Heating Time |
+20℃~+150℃ < 45mins, Average heating rate:1-3 ℃/min |
||||||||
Cooling Time |
+20℃~-70℃ < 75mins, Average cooling rate:0.7℃~1.0 ℃/min |
||||||||
WxHxD(cm) |
inner box | 40*50*40 | 50*60*40 | 50*60*50 | 20*75*60 | 60*85*60 | 60*85*80 | 100*100*80 |
100*100*100 |
outer box | 90*143*85 | 100*153*85 | 100*153*95 | 100*168*105 | 100*178*125 | 110*178*105 | 150*193*125 |
150*193*145 |
|
Structural material |
External Box |
High-class SUS304# Heat & cold resistance stainless steel |
|||||||
Internal Box |
High-class SUS304# |
||||||||
Refrigeration system |
Air-cooled European and American original imported fully closed or semi-closed compressor unit, heat dissipation plate evaporator | ||||||||
Heating and Humidification System |
Heating: Stainless steel finned heating tube heating air; humidification; 316L stainless steel sheathed electric heating evaporation. |
||||||||
Safety protection device |
No fuse overload protection, compressor overpressure protection, compressor overcurrent/overload protection, fan overcurrent protection, short circuit protection, leakage protection | ||||||||
Standard configuration |
View window (240x350mm), test hole (diameter 50mm), material frame x 2, window lamp |
||||||||
Power (KW) |
2.3-5.2 |
2.8-6.0 |
3.5-6.5 |
3.8-8.5 |
3.8-8.5 |
4.2-11 |
9-17 |
9.5-19 |
|
Weight (KG) |
220 |
210 |
230 |
250 |
300 |
320 |
460 |
400 |
|
Power Supply |
AC1Φ3W220V/ AC3Φ5W380V50/60Hz |