LT – WY02 Constant temperature water nozzle comprehensive performance testing machine
Technical Parameters
The serial number |
According to project name |
Want to ask |
1 |
Work pressure |
0.1 ~ 1.0 MPa |
2 |
Hydraulic resolution |
0.001 MPa |
3 |
Temperature range |
0 ~ 100.0 ℃ |
4 |
The temperature precision |
±1℃, can be displayed to 0.1℃ |
5 |
Pressure sensor range |
0 ~ 1.0 MPa |
6 |
Pressure sensor accuracy |
0.5% accuracy |
7 |
Flow sensor range |
2 ~ 30 LPM |
8 |
Flow sensor accuracy |
1% accuracy |
9 |
Temperature sensor range of outlet |
0 ~ 100 ℃ |
10 |
Accuracy of outlet temperature sensor |
Plus or minus 0.5 ℃ |
11 |
Time range |
1 second ~ 600 minutes adjustable |
12 |
Time precision |
Plus or minus 0.02 seconds |
Comply with standards and clauses |
Product class |
Standard said |
Article standards |
Temperature control water mouth |
QB 2806-2017 |
8.7.2 sealing performance |
Temperature control water mouth |
QB 2806-2017 |
8.7.4 stability of outlet water temperature |
Temperature control water mouth |
QB 2806-2017 |
8.7.5 security |
Temperature control water mouth |
QB 2806-2017 |
8.7.6 maximum outlet water temperature |
Nc constant temperature nozzle |
GB/T 24293-2009 |
7.4.7 stability of outlet water temperature |
Nc constant temperature nozzle |
GB/T 24293-2009 |
7.4.8 outlet water temperature, output water test and maximum outlet water temperature at loss of cold water supply |
Nc constant temperature nozzle |
GB/T 24293-2009 |
7.4.9 initial temperature setting |
Nc constant temperature nozzle |
GB/T 24293-2009 |
7.4.10 energy consumption test of the whole machine |
Inductive temperature-controlled nozzle |
QB/T 4000-2010 |
7.9.8 stability of outlet water temperature |
Inductive temperature-controlled nozzle |
QB/T 4000-2010 |
7.9.9 security testing |
Automatic Compensating Valves |
ASSE1016-2011. |
4.2.2 High - temperature conditioning |
Automatic Compensating Valves |
ASSE1016-2011. |
4.3 Working pressure test |
Automatic Compensating Valves |
ASSE1016-2011. |
4.4 Maximum operating torque or force adjustment test |
Automatic Compensating Valves |
ASSE1016-2011. |
4.6 Pressure and temperature variation test |
Automatic Compensating Valves |
ASSE1016-2011. |
4.7 Water supply failure test |
Automatic Compensating Valves |
ASSE1016-2011. |
4.8 Mechanical temperature limit stop test |
Automatic Compensating Valves |
ASSE1016-2011. |
4.9 Outlet temperature and flow capacity test |